Search results

1 – 2 of 2
Article
Publication date: 1 January 2024

Hongya Niu, Chunmiao Wu, Xinyi Ma, Xiaoteng Ji, Yuting Tian and Jinxi Wang

This study aims to better understand the morphological characteristics of single particle and the health risk characteristics of heavy metals in PM2.5 in different functional…

Abstract

Purpose

This study aims to better understand the morphological characteristics of single particle and the health risk characteristics of heavy metals in PM2.5 in different functional areas of Handan City.

Design/methodology/approach

High resolution transmission electron microscopy was used to observe the aerosol samples collected from different functional areas of Handan City. The morphology and size distribution of the particles collected on hazy and clear days were compared. The health risk evaluation model was applied to evaluate the hazardous effects of particles on human health in different functional areas on hazy days.

Findings

The results show that the particulate matter in different functional areas is dominated by spherical particles in different weather conditions. In particular, the proportion of spherical particles exceeds 70% on the haze day, and the percentage of soot aggregates increases significantly on the clear day. The percentage of each type of particle in the teaching and living areas varied less under different weather conditions. Except for the industrial area, the size distribution of each type of particle in haze samples is larger than that on the clear day. Spherical particles contribute more to the small particle size segment. Soot aggregate and other shaped particles contribute more to the large size segment. The mass concentrations of hazardous elements (HEs) in PM2.5 in different functional areas on consecutive haze pollution days were illustrated as industrial area > traffic area > living area > teaching area. Compared with the other functional areas, the teaching area had the lowest noncarcinogenic risk of HEs. The lifetime carcinogenic risk values of Cr and As elements in each functional area have exceeded residents’ threshold levels and are at high risk of carcinogenicity. Among the four functional areas, the industrial area has the highest carcinogenic and noncarcinogenic risks. But the effects of HEs on human health in the other functional areas should also be taken seriously and continuously controlled.

Originality/value

The significance of the study is to further understand the morphological characteristics of single particles and the health risks of heavy metals in different functional areas of Handan City. the authors hope to provide a reference for other coal-burning industrial cities to develop plans to improve air quality and human respiratory health.

Details

World Journal of Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 4 November 2022

Zhiguo Tang, Feng Deng, Yongtao Ji and Jianping Cheng

The purpose of this paper is to improve the overall heat transfer performance and the temperature uniformity of the heat sink and to explore the effects of the jet Reynolds number…

Abstract

Purpose

The purpose of this paper is to improve the overall heat transfer performance and the temperature uniformity of the heat sink and to explore the effects of the jet Reynolds number and the nanoparticle volume fraction of the nanofluids on the flow and heat transfer performance.

Design/methodology/approach

A heat sink with discontinuous arc protrusions in the wall jet region is proposed for confined slot jet impingement. A sloping upper cover plate is added to improve the heat transfer effect in this area. An Al2O3–water nanofluid is selected as the working fluid of the jet for better heat transfer. The Standard k-e turbulence model is used for numerical calculation. The key structural parameters of the heat sink are optimized by the response surface method and a genetic algorithm. The effects of the jet Reynolds number (Re) and the nanofluid concentration (ϕ) on the flow and heat transfer performance of the optimized heat sink are investigated.

Findings

The average Nusselt number of the optimal heat sink is 8.2% higher and the friction resistance is 5.9% lower than that of the initial flat plate heat sink when ϕ = 0.02 and Re = 8,000. The discontinuous arc protrusions and the sloping upper cover plate substantially enhance the heat transfer in the later stage of jet development, improving the temperature uniformity of the heat sink. The maximum temperature difference of the optimal heat sink is 28.1% lower than that of the flat plate heat sink at the same nozzle height. As the jet Reynolds number and the nanofluid particle concentration increase, the Nusselt number of the optimized heat sink and the friction coefficients increase, resulting in a decrease in the evaluation coefficient. However, the overall temperature uniformity of the heat sink is improved under all conditions.

Originality/value

The novel heat sink structure provides a new way to enhance the heat transfer and temperature uniformity of confined slot jet impingement. The flow and heat transfer performance of the heat sink impinged by confined slot jet of nanofluids are obtained. The combination of response surface method and genetic algorithm can be applied to the multi-objective optimization of heat resistance and flow resistance of heat sink.

Details

International Journal of Numerical Methods for Heat & Fluid Flow, vol. 33 no. 3
Type: Research Article
ISSN: 0961-5539

Keywords

1 – 2 of 2