Article
Publication date: 29 October 2021

Norsafiah Norazman, Adi Irfan Che-Ani, Afifuddin Husairi Mat Jusoh Hussain and Wan Norisma Wan Ismail

The existing concept in the building rating scheme especially in developing countries was more focused on the environment, economic, social and culture. The new approach of the…

Abstract

Purpose

The existing concept in the building rating scheme especially in developing countries was more focused on the environment, economic, social and culture. The new approach of the classroom condition index (CCI) assessment scheme has its uniqueness in environmental and social aspects because of high building performance in secondary school buildings. The requirements set by the Ministry of Education Malaysia include providing a conducive learning environment, especially for students who are considered as the main users of classrooms in school buildings. Currently, the school administration needs to manually record the condition of the classroom to increase its comfort level. The lack of a structured scheme for classroom assessment makes it difficult for school administration to focus on the overall classroom condition (physical environmental aspect) in the school building. The purpose of this study is to develop a framework for classroom conditions by proposing a CCI assessment scheme for a secondary school building in Malaysia.

Design/methodology/approach

Mixed methods were used to carry out the study. The first stage of this study concentrates on developing a system for CCI that relates to physical elements in the classroom. This is done by reviewing the literature on the classroom physical performance, as well as a comparison between several building rating systems locally and abroad. The structure of the proposed CCI scheme is grouped into four main themes, namely, space management quality (SMQ), building condition (BC), indoor environmental quality (IEQ) and teaching and learning quality (TLQ). In addition, there are 12 categories and 23 indicators listed under this theme. The second stage focuses on formulating assessment categories with their relevant performance indicators. This phase undergoes a validation process by conducting a survey (questionnaire) toward the classroom’s main users, which are students and teachers. This is to ensure the accuracy of classroom conditions in the school building. A semi-structured interview was also conducted among building experts. They are building surveyors, building engineers, building designers and building performance experts to support the main findings in the second stage. Relative importance (RI) index approach has been applied to show the indicators weighting and ranking are used as data collections method by using Statistical Package of Social Science software to examine the RI of each category and indicator, respectively.

Findings

The findings show that prominent RI and balanced weights are formed from these four main themes. They are SMQ (19.9%), BC (26.6%), IEQ (33.2%) and TLQ (20.3%). The outcome of this study will contribute to a detailed assessment scheme for CCI at the secondary school building. The contribution of the CCI Assessment Scheme is more comprehensive and holistic than the conventional assessment process for BCs. It focuses specifically on classroom space as it is the most important area to achieve a high level of comfort comparing to other spaces in the school building. This holistic approach encompasses all types of classrooms. The concept of one tool fits all is seen as no longer a relevant adaptation in this context. This proposed tool is to be used only for the classroom (as the name CCI implies) and it cannot be used for the other types of spaces, for instance, teacher room, library, meeting room, toilet, canteen and, etc. This is because different spaces represent different physical indicators to be classified. This, in turn, contributes to a conducive learning environment for students in the school.

Originality/value

This paper provides the current information, knowledge and findings related to the classroom physical indicators in developing the assessment scheme for the classroom environment. It will assist both technical and non-technical experts to clarify the current condition of classroom physical performance that ideally may affect the students’ learning environment. The novelty of CCI development is not only on the adopted method but it also includes the ideas on next generation model of rating system that ideally need specific indicators and weighting to be generated into an intelligent computerized system.

Details

Journal of Facilities Management , vol. 21 no. 2
Type: Research Article
ISSN: 1472-5967

Keywords

Article
Publication date: 11 May 2023

Norsafiah Norazman, Siti Nurul Asma’ Mohd Nashruddin and Adi Irfan Che-Ani

Urban population growth has increased housing density, which has expanded the construction of low-cost low-rise residential in urban areas. Good building performance and effective…

Abstract

Purpose

Urban population growth has increased housing density, which has expanded the construction of low-cost low-rise residential in urban areas. Good building performance and effective low-cost low-rise residential quality lead to higher user satisfaction and improve building sustainability. This study aims to focus on the factors influencing the sustainability of low-cost low-rise residential in the West Malaysia urban area to assess resident satisfaction.

Design/methodology/approach

A mixed-mode approach with both qualitative and quantitative were used in this study. Semi-structured interviews were conducted with 12 stakeholders to identify the common factors influencing sustainability in low-cost low-rise residential. Subsequently, questionnaire surveys were formed and distributed among building users to determine the satisfaction level with low-cost low-rise residential building performance.

Findings

The finding demonstrates that accessibility is the key factor to achieving sustainability of low-cost low-rise residential. The finding also related to the factor that influences both stakeholders and building user satisfaction levels. This study also identifies key areas that require attention to improve user satisfaction with building sustainability and building performance of low-cost low-rise residential.

Originality/value

This study aims to determine stakeholder and building user satisfaction levels in relation to the sustainable building factor. A few indicators have been set up to identify the factors that most influence the sustainability and environment of low-cost low-rise residential buildings. Each subchapter has a few recommendations to improve the performance of low-cost low-rise residential. Each of the factors mentioned is related to social, economic and environmental sustainability. In addition, the study discovered a strong connection between low-cost low-rise residential performance and user satisfaction.

Details

Journal of Facilities Management , vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1472-5967

Keywords

Article
Publication date: 31 May 2023

Naziah Salleh, Agus Salim Nuzaihan Aras, Norsafiah Norazman and Syahrul Nizam Kamaruzzaman

This paper aims to evaluate the level of compliance of fire safety with the legal requirements in Malaysia government hospital buildings by evaluating via fire risk management.

Abstract

Purpose

This paper aims to evaluate the level of compliance of fire safety with the legal requirements in Malaysia government hospital buildings by evaluating via fire risk management.

Design/methodology/approach

Five government hospitals were selected. These five hospitals were selected due to the location of Penang, which is one of the fast-growing states in Malaysia (Salleh, 2019; Ebekozien, 2019). This state is the second most densely populated state after Wilayah Persekutuan Kuala Lumpur, with an average distribution of 1,490 persons per square km. This higher population caused the higher demand on the health-care services by the public (DOSM, 2016). The observation and building audit processes are as described. Hundreds of photos were taken for qualitative analysis, and all fire safety elements were measured for the descriptive analysis for each hospital. The framework of audit elements is created based on the Life Safety Code: NFPA 101 (2018), UBBL 1984: Part VII (Fire Requirements) and Part VIIII (Fire Alarms, Fire Detection, Fire Extinguishment and Fire Fighting Access). The cross-sectional descriptive evaluation is conducted in the case studies building in accordance with Life Safety Code of NFPA, also known as NFPA 101. To conduct the study, the information needed to assess the fire safety status was extracted from the CFSES software based on the NFPA 101 standard and prepared and compiled by the researcher as a checklist. In the next stage, gathered information was analysed using Computerised Fire Safety Evaluation System (CFSES) software. This method was developed based on the NFPA 101 standard and evaluated the fire risk from four dimensions of containment, extinguishment, people movement and general safety. This software gives the risk assessment results in three areas of fire control, exits and general safety. To assess the fire risk of the commercial buildings after entering the background information (height, age, number of stories, etc.) in the software, the software first calculates the score that the building should obtain in the three aspects of fire control, exit routes and general safety (minimum score required).

Findings

The utmost zones in the case studies (44.3%) occupied by limited mobility are located at low-rise buildings or at the first floor to third floor of the hospital buildings. Hospitals managements lacked in creating the maximum exit route and egress the occupants to disclosed the building during evacuation, it correlates to the patients' mobility positions strategy to assign their categories that fell on effortless mobilisation. Surveyed hospitals were built with the non-combustible materials, even though four of the case studies were built before 1984. Hospitals were equipped with hazard separations and vertical smoke pores, and in most of the zones, sprinkler system is installed only in the corridors, equipped with communication system and system of communication with fire and relief organisations and has a fire detection and alarm system throughout the building. Results of fire risk assessment on four groups of elements were tested via CFSES revealed from 122 zones of surveyed hospitals; 102 or 84% of zones give the highest failed rate to comply the NFPA 101 requirements in terms of people movement in the building. The high-occupied Penang General Hospital contributed as the highest case study for not complying with the minimum requirements in all dimensions: people movement elements (41 zones), fire containment (31 zones), fire extinguisher (31 zones) and general safety (20). Fire extinguishment (62 zones) recorded the highest numbers of zones that complied with NFPA 101 (2013). The overall results of the fire risk assessment suggested that in terms of the fire control, egress and general safety aspects, the fire risk assessment score was unacceptable (failed) in all hospital buildings studied, and in the three areas mentioned, the general safety, egress/exit routes and fire control were in a worse status in terms of the score obtained in the software. None of the surveyed hospital received the minimum safety score in the three areas mentioned. The involvement of Emergency Response Team is crucial to overcome this egress or fire exit requirement and parameters.

Research limitations/implications

Several limitations exist in this research that cannot be controlled. Firstly, the occupancy rates only determined during peak hour. Accessibility into hospital compound permitted only during daytime. Secondly, the fire safety audits and fire safety risk management in this research are not being conducted by a professional architect or engineer and as a result must be relied on the direct inspection checklist to create valid results. Thirdly, this research has some limitations which need to be noted but does not affect the robustness of the study’s findings. This study focuses only on five selected public hospitals in one state of the northern region of Malaysia and excluded data gathering from all other parts of Malaysia. The perception of hospital operators regarding fire safety issues from different state hospitals may allow comparisons.

Practical implications

The findings of this paper should make a key practical contribution to the body of knowledge. In practice, the proposed framework should expand the knowledge of public hospital fire safety management plan concerning the level of fire safety compliance with the requirements in government hospital buildings and develop a fire safety management plan framework for government hospital buildings.

Social implications

This paper develops an early framework component related to the occupants’ safety which gives the basis for future research in hospital fire safety settings as it imparts early investigation into the consequence of investigating the phenomenon from the operators’ perspective as an attempt to improve public health-care fire safety performance in hospitals.

Originality/value

This paper has created a few measurement tools that can be applied among public hospital buildings stakeholders to perform the fire safety audit and risk management and rate the performance of Fire Safety Management in public hospitals.

Details

Journal of Facilities Management , vol. 21 no. 4
Type: Research Article
ISSN: 1472-5967

Keywords

Article
Publication date: 10 January 2023

Norsafiah Norazman, Naziah Muhamad Salleh, Siti Nurul Asma' Mohd Nashruddin and Wan Norisma Wan Ismail

Retrofitting and rehabilitation are part of the conservation approach in Heritage Building Conservation Guideline 2016 in Malaysia. Heritage buildings can be retrofitted to…

Abstract

Purpose

Retrofitting and rehabilitation are part of the conservation approach in Heritage Building Conservation Guideline 2016 in Malaysia. Heritage buildings can be retrofitted to preserve their culture and history while being given a new lease. Rehabilitation is a preservation requirement that is more flexible since it assumes that the structure has already deteriorated to the point where repairs are required to prevent further deterioration. Although the strategies of these two approaches are different, their combination resulted in sustainable heritage building maintenance. This long-term maintenance strategy is necessary, especially for Malaysia's numerous heritage schools, which have serious maintenance problems as a result of infrequent maintenance, repairs, and funding shortages.

Design/methodology/approach

This study involved secondary data from an intensive literature review along with a comparative study from articles review and context analysis. A comparative study was conducted to determine the typical issue with heritage school buildings and the best maintenance practice for these structures. Finally, it involved a SWOT analysis study of retrofitting and rehabilitating heritage school buildings will be discussed in this study as well.

Findings

The findings of this study will focus on developing a strategic planning framework and maintenance for heritage school buildings in Malaysia to achieve sustainable maintenance. It will also highlight sustainable maintenance best practices for heritage school buildings in Malaysia. Finally, SWOT analysis will go over the pros and cons of retrofitting and rehabilitation for these buildings.

Originality/value

This paper put forward the requirements of strategic planning in heritage school buildings and outlines the significance of sustainable maintenance for educational buildings. It is an alternative for cost savings that has not been extensively investigated in previous studies.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 26 June 2019

Norsafiah Norazman, Adi Irfan Che-Ani, Nor Haslina Ja’afar and Muhamad Azry Khoiry

Teaching and learning processes are conducted formally in a classroom as the main learning space for schooling system, where it should be implemented effectively to achieve a…

Abstract

Purpose

Teaching and learning processes are conducted formally in a classroom as the main learning space for schooling system, where it should be implemented effectively to achieve a desired level of satisfaction and comfort for the students. To encourage and sustain students’ motivation for continuous learning, specifically at secondary school level, classroom capacity is increasing significantly. The purpose of this paper is to analyse the guidelines and regulations of building design standard compliance, specifically for classrooms, and suggest the suitability of classroom capacity based on two main courses offered at the secondary school level.

Design/methodology/approach

Two sets of perimeters were used in this study to gauge the intended results, namely, mixed method was used to carry out the study. The first indicator was a quantitative method whereby the current area of 20 selected classrooms (length × width) was physically measured and recorded. The second indicator used was a qualitative method, through a semi-structured interview.

Findings

The findings showed that 55 per cent of classroom capacity in secondary school buildings complied with the existing guidelines, the stipulated design regulations and the classroom area requirement. The current area of classroom standing is at 2.25 m2 per student with an observable increase in students’ satisfaction during the teaching and learning processes. However, the findings from the semi-structured interview highlighted interesting points in relation to the suitability of classroom capacity. The teachers felt that classroom capacity affected performance of students based on two categories, namely, classroom-centred learning and classroom-less learning. The respondents agreed that the classroom-centred learning approach and classroom-less learning approach worked best with a maximum of 22 and 30 students per classroom, respectively.

Originality/value

This paper provides the current information, knowledge and findings related with real classroom capacity at a secondary school building that may affect students’ performance, while focus had always been on types of classroom, gadgets and qualified teaching staff. Hardly any valuable attention is given to the space these students spend almost a good part of their day for the rest of the week, over their formative learning period. Perhaps like the model of cars and sitting capacity, model classroom area and maximum capacity explored to ensure objectives irrespective of the driver, the teacher of the class. Therefore, these indicators may assist the school building management, building facilities and other professionals to identify and implement suitable of classroom capacity especially for all classroom-based learning in the schools generally.

Details

Journal of Facilities Management , vol. 17 no. 3
Type: Research Article
ISSN: 1472-5967